IBM Brocade SAN Zonning 하는 방법System of Infra/SAN 2022. 1. 24. 23:15728x90반응형
IBM Brocade SAN Zonning 하는 방법
IBM_NEW_SAN_2498_B24:admin> switchshow switchName: IBM_NEW_SAN_2498_B24 switchType: 71.2 switchState: Online switchMode: Native switchRole: Principal switchDomain: 100 switchId: fffc64 switchWwn: 10:00:00:05:33:3d:01:10 zoning: ON (TESTSAN_cfg) switchBeacon: OFF Index Port Address Media Speed State Proto ============================================== 0 0 640000 id N8 Online FC F-Port 50:05:07:68:02:10:69:1e 1 1 640100 id N8 Online FC F-Port 50:05:07:68:02:20:69:1e 2 2 640200 id N8 Online FC F-Port 50:05:07:68:02:30:69:1e 3 3 640300 id N8 Online FC F-Port 50:05:07:68:02:40:69:1e 4 4 640400 id N8 Online FC F-Port 50:05:07:68:02:10:69:1f 5 5 640500 id N8 Online FC F-Port 50:05:07:68:02:20:69:1f 6 6 640600 id N8 Online FC F-Port 50:05:07:68:02:30:69:1f 7 7 640700 id N8 Online FC F-Port 50:05:07:68:02:40:69:1f 8 8 640800 id N8 Online FC F-Port 21:00:00:24:ff:34:2d:18 9 9 640900 id N8 Online FC F-Port 21:00:00:24:ff:34:2d:19 10 10 640a00 id N8 Online FC F-Port 21:00:00:24:ff:34:31:20
▶ Brocade SAN Switch에서 switchshow 명령어를 통해서 SAN Switch의 포트 모듈의 현황을 확인할 수 있고 각 포트별로 할당된 WWPN에 대한 정보를 확인할 수 있습니다. 현재 10 Port의 SAN 포트가 있는 것을 확인할 수 있습니다.
IBM_NEW_SAN_2498_B24:admin> alicreate "P0_IBMSVR_FCS1","1,0" IBM_NEW_SAN_2498_B24:admin> alicreate "P1_IBMSVR_FCS2","1,1" IBM_NEW_SAN_2498_B24:admin> alicreate "P2_IBMSVR_FCS3","1,2" IBM_NEW_SAN_2498_B24:admin> alicreate "P3_IBMSVR_FCS4","1,3"
▶ 위에서 해당 SAN스위치에서 포트에 대해서 확인을 했고 각 포트마다 Alias라는 이름 명칭을 줄 수 있습니다. 명시적으로 해당 포트에 대한 별명이라고 생각하시면 되겠습니다.
IBM_NEW_SAN_2498_B24:admin> cfgsave You are about to save the Defined zoning configuration. This action will only save the changes on Defined configuration. Any changes made on the Effective configuration will not take effect until it is re-enabled. Do you want to save Defined zoning configuration only? (yes, y, no, n): [no] yes Updating flash ...
▶ Alias를 지정해주고 SAN스위치에 대한 Config 정보를 cfgsave 명령어를 통해서 저장하도록 합니다. 마지막에 정의된 구성 정보를 저장하겠냐는 질문에 yes를 텍스트로 입력합니다.
IBM_NEW_SAN_2498_B24:admin> cfgshow | grep alias: alias: P0_IBMSVR_FCS1 alias: P1_IBMSVR_FCS2 alias: P2_IBMSVR_FCS3 alias: P3_IBMSVR_FCS4
▶ cfgsave 후에 cfgshow 명령어를 통해서 Alias 항목이 정확하게 표기가 되었는지 확인을 할 수 있습니다. 위에서 언급했던 그대로의 Alias 별칭이 지정된 것을 확인할 수 있습니다.
IBM_NEW_SAN_2498_B24:admin> alicreate "P7_IBMSTORAGE_FCS1","1,7" IBM_NEW_SAN_2498_B24:admin> alicreate "P8_IBMSTORAGE_FCS1","1,8" IBM_NEW_SAN_2498_B24:admin> alicreate "P9_IBMSTORAGE_FCS1","1,9" IBM_NEW_SAN_2498_B24:admin> alicreate "P10_IBMSTORAGE_FCS1","1,10"
▶ 다음으로는 위에서 서버에 대한 Alias 별칭을 지정한 것 처럼 뒤에서 Zonning을 하기 전에 스토리지 포트에 대한 Alias 지정을 해주도록 합니다. Zonning시 명시적으로 헷갈리지 않기 위해서 서버와 스토리지간의 포트 별칭을 통해서 쉽게 구별하기 위해서 동일하게 진행을 해주도록 합니다.
IBM_NEW_SAN_2498_B24:admin> cfgsave You are about to save the Defined zoning configuration. This action will only save the changes on Defined configuration. Any changes made on the Effective configuration will not take effect until it is re-enabled. Do you want to save Defined zoning configuration only? (yes, y, no, n): [no] yes Updating flash ...
▶ Alias를 지정해주고 SAN스위치에 대한 Config 정보를 cfgsave 명령어를 통해서 저장하도록 합니다. 마지막에 정의된 구성 정보를 저장하겠냐는 질문에 yes를 텍스트로 입력합니다.
IBM_NEW_SAN_2498_B24:admin> cfgshow | grep -i IBMSTORAGE alias: P7_IBMSTORAGE_FCS1 alias: P8_IBMSTORAGE_FCS1 alias: P9_IBMSTORAGE_FCS1 alias: P10_IBMSTORAGE_FCS1
▶ cfgsave 후에 cfgshow 명령어를 통해서 Alias 항목이 정확하게 표기가 되었는지 확인을 할 수 있습니다. 위에서 언급했던 그대로의 Alias 별칭이 지정된 것을 확인할 수 있습니다. 하지만 위에서 Alias의 Description을 수행할 때 FCS1번으로 통일하여 별칭을 만들어서 잘못 생성된 것을 확인할 수 있습니다.
IBM_NEW_SAN_2498_B24:admin> alicreate "P7_IBMSTORAGE_FCS1","1,7" IBM_NEW_SAN_2498_B24:admin> alicreate "P8_IBMSTORAGE_FCS2","1,8" IBM_NEW_SAN_2498_B24:admin> alicreate "P9_IBMSTORAGE_FCS3","1,9" IBM_NEW_SAN_2498_B24:admin> alicreate "P10_IBMSTORAGE_FCS4","1,10"
▶ 스토리지 쪽의 Alias 별칭을 삭제하기 전에 다시 한번 생성을 해주도록 합니다. 이번에는 1,2,3,4로 생성을 해주어 SAN스위치 포트의 7,8,9,10번이 스토리지 FC Port의 1,2,3,4번을 사용한다는 것을 명시적으로 지정해주도록 합니다.
IBM_NEW_SAN_2498_B24:admin> cfgshow | grep -i IBMSTORAGE alias: P7_IBMSTORAGE_FCS1 alias: P8_IBMSTORAGE_FCS2 alias: P9_IBMSTORAGE_FCS3 alias: P10_IBMSTORAGE_FCS4
▶ cfgsave 후에 cfgshow 명령어를 통해서 Alias 항목이 정확하게 표기가 되었는지 확인을 할 수 있습니다. 위에서 언급 했던 그대로의 Alias 별칭이 지정된 것을 확인할 수 있습니다.
IBM_NEW_SAN_2498_B24:admin> alidelete "P8_IBMSTORAGE_FCS1" IBM_NEW_SAN_2498_B24:admin> alidelete "P9_IBMSTORAGE_FCS1" IBM_NEW_SAN_2498_B24:admin> alidelete "P10_IBMSTORAGE_FCS1"
▶ 기존에 잘못 생성된 Alias 별칭을 alidelete를 통해서 삭제하도록 합니다. 삭제 뒤 기존 alishow의 명령어를 통해서 삭제가 됐는지 확인을 하도록 합니다.
zonecreate "P0_IBMVSVR_FCS1_P7_IBMSTORAGE_FCS1","P0_IBMSVR_FCS1;P7_IBMSTORAGE_FCS1" zonecreate "P1_IBMSVR_FCS2_P8_IBMSTORAGE_FCS2","P1_IBMSVR_FCS2;P8_IBMSTORAGE_FCS2" zonecreate "P2_IBMSVR_FCS3_P9_IBMSTORAGE_FCS3","P2_IBMSVR_FCS3;P9_IBMSTORAGE_FCS3" zonecreate "P3_IBMSVR_FCS4_P10_IBMSTORAGE_FCS4","P3_IBMSVR_FCS4;P10_IBMSTORAGE_FCS4"
▶ 다음으로는 서버 포트와 스토리지 포트 간에 Zonning을 하기전에 하나의 약속처럼 Zone을 생성하여 규칙을 만들도록 하겠습니다. Zonecreate를 통해서 해당 포트 간의 Zone을 생성합니다.(Portzonnig)
IBM_NEW_SAN_2498_B24:admin> cfgsave You are about to save the Defined zoning configuration. This action will only save the changes on Defined configuration. Any changes made on the Effective configuration will not take effect until it is re-enabled. Do you want to save Defined zoning configuration only? (yes, y, no, n): [no] yes Updating flash ...
▶ Zone 생성후 cfgsave를 통해서 SAN 스위치의 Config 정보를 저장하도록 합니다.
IBM_NEW_SAN_2498_B24:admin> zoneshow zone: P0_IBMVTL_FCS1_P7_IBMSTORAGE_FCS1 P0_IBMVTL_FCS1; P7_IBMSTORAGE_FCS1 zone: P1_IBMVTL_FCS2_P8_IBMSTORAGE_FCS2 P1_IBMVTL_FCS2; P8_IBMSTORAGE_FCS2 zone: P2_IBMVTL_FCS3_P9_IBMSTORAGE_FCS3 P2_IBMVTL_FCS3; P9_IBMSTORAGE_FCS3 zone: P3_IBMVTL_FCS4_P10_IBMSTORAGE_FCS4 P3_IBMVTL_FCS4; P10_IBMSTORAGE_FCS4
▶ Zone을 생성하게 되면 zoneshow 명령어를 통해서 서버와 스토리지 간에 약속을 한 것처럼 생성된 Zone 안에 구성이 되어 있는 것을 확인할 수 있습니다.
IBM_NEW_SAN_2498_B24:admin> cfgadd "TESTSAN_cfg","P0_IBMVTL_FCS1_P7_IBMSTORAGE_FCS1" IBM_NEW_SAN_2498_B24:admin> cfgadd "TESTSAN_cfg","P1_IBMVTL_FCS2_P8_IBMSTORAGE_FCS2" IBM_NEW_SAN_2498_B24:admin> cfgadd "TESTSAN_cfg","P2_IBMVTL_FCS3_P9_IBMSTORAGE_FCS3" IBM_NEW_SAN_2498_B24:admin> cfgadd "TESTSAN_cfg","P3_IBMVTL_FCS4_P10_IBMSTORAGE_FCS4"
▶ 해당 정보를 cfgadd를 통해서 넣어주도록 합니다. 현재 SAN스위치의 zonnig name인 "TESTSAN_cfg" 현재 정보를 추가해주도록 합니다.
IBM_NEW_SAN_2498_B24:admin> cfgsave You are about to save the Defined zoning configuration. This action will only save the changes on Defined configuration. Any changes made on the Effective configuration will not take effect until it is re-enabled. Do you want to save Defined zoning configuration only? (yes, y, no, n): [no] yes Updating flash ...
▶ Alias생성, Zone생성을 통해서 SAN스위치에 대한 Config 정보를 cfgsave 명령어를 통해서 저장하도록 합니다. 마지막에 정의된 구성 정보를 저장하겠냐는 질문에 yes를 텍스트로 입력합니다.
IBM_NEW_SAN_2498_B24:admin> cfgenable TESTSAN_cfg You are about to enable a new zoning configuration. This action will replace the old zoning configuration with the current configuration selected. If the update includes changes to one or more traffic isolation zones, the update may result in localized disruption to traffic on ports associated with the traffic isolation zone changes Do you want to enable 'TESTSAN_cfg' configuration (yes, y, no, n): [no] yes zone config "TESTSAN_cfg" is in effect Updating flash ...
▶ 마지막으로 cfgadd한 내용을 바탕으로 현재 zonning 정보에 대해서 enable 하겠다는 cfgenable TESTSAN_cfg를 수행하여 SAN 스위치에 저장을 하여 사용을 하도록 합니다.
IBM_NEW_SAN_2498_B24:admin> cfgshow Effective configuration: cfg: TESTSAN_cfg zone: P0_IBMVTL_FCS1_P7_IBMSTORAGE_FCS1 1,0 1,7 zone: P1_IBMVTL_FCS2_P8_IBMSTORAGE_FCS2 1,1 1,8 zone: P2_IBMVTL_FCS3_P9_IBMSTORAGE_FCS3 1,2 1,9 zone: P3_IBMVTL_FCS4_P10_IBMSTORAGE_FCS4 1,3 1,10
▶ cfgshow를 통해서 zone의 상태와 alias의 상태를 동시에 확인할 수 있습니다.
반응형2021.12.29 - [System of Infra/Network And SAN] - IBM Brocade SAN 스위치 IP 주소 변경하는 방법
IBM Brocade SAN 스위치 IP 주소 변경하는 방법
IBM Brocade SAN 스위치 IP 주소 변경하는 방법 IBM_SAN_2498_B24:admin> ipaddrshow SWITCH Ethernet IP Address: 10.50.1.30 Ethernet Subnetmask: 255.255.255.0 Gateway IP Address: 10.50.1.1 DHCP:..
pinetreeday.tistory.com
2021.12.29 - [System of Infra/Network And SAN] - IBM Brocade SAN 스위치 포트 Speed 변경하는 방법
IBM Brocade SAN 스위치 포트 Speed 변경하는 방법
IBM Brocade SAN 스위치 포트 Speed 변경하는 방법 IBM_NEW_SAN_2498_B24:admin> switchshow switchName: IBM_NEW_SAN_2498_B24 switchType: 71.2 switchState: Online switchMode: Native switchRole: Pr..
pinetreeday.tistory.com
PS. 포스팅의 내용은 제 기준으로 작성한 것이기 때문에 참고해서 보시면 감사하겠습니다.
포스팅 과정의 오류 및 오타 그리고 궁금한 점에 대해서는 댓글 남겨주세요.