-
Nutanix Certified Professional (NCP-MCI) 6.5 문제 풀이 (1)IT Certificate/Nutanix Certification 2024. 12. 29. 16:36728x90반응형
▣ Nutanix Certified Professional (NCP-MCI) 6.5 문제 풀이 (1)
Question #1
After logging into Prism Element, an administrator presses the letter A on the keyboard. What is the expected outcome of this input?
A. Analysis page will launch.
B. Alerts page will launch.
C. About Nutanix page will launch.
D. API Explorer page will launch.
더보기Question #1
[문제] Prism Element에 로그인한 후, 관리자가 키보드의 문자 A를 누릅니다. 이 입력의 예상 결과는 무엇입니까?
[정답] B. Alerts page will launch.
[해설] Prism Element에 로그인한 후 키보드에서 문자 "A"를 누르면 알림(Alerts) 페이지가 실행
Question #2
The Update Source for LCM has been configured as shown in the exhibit. Inventory is failing consistently.
What is the likely cause of this issue?
A. Port 80 is blocked by a firewall.
B. The administrator does not have a valid portal account.
C. The license assigned to the cluster has expired.
D. Port 443 is blocked by a firewall.
더보기Question #2
[문제] LCM의 업데이트 소스가 Exhibit(첨부된 그림)과 같이 구성되었습니다. Inventory 작업이 계속해서 실패하고 있습니다. 이 문제의 가장 가능성 높은 원인은 무엇입니까?
[정답] D. Port 443 is blocked by a firewall.
[해설] Nutanix Portal에 HTTPS로 연결하기 위해서는 포트 443이 오픈되어야 있어야 함.. 포트 443이 방화벽에 의해 차단된 경우, LCM이 Nutanix Portal로 연결을 시도할 때 실패
Question #3
An administrator has created a Nutanix managed network, and assigned it a VLAN ID of 512. Several VMs have been created, and the administrator notices that the VMs can successfully communicate with other VMs on that VLAN, provided they are on the same host, but cannot communicate with VMs that reside on different hosts in the cluster. What is most likely the cause of this issue?
A. There is a firewall rule blocking VLAN512 traffic.
B. The VLAN was not created on the upstream switches.
C. The administrator did not create the VLAN on all hosts.
D. VLAN512 is a reserved VLAN ID, and not usable for guest VMs.
더보기Question #3
[문제] 관리자가 Nutanix 관리 네트워크를 생성하고 VLAN ID로 512를 할당했습니다. 여러 VM(가상 머신)이 생성되었으며, 관리자는 동일한 VLAN에 있는 다른 VM과 통신할 수 있음을 확인했습니다. 단, 동일한 호스트에 있는 VM 간에는 통신이 가능하지만, 클러스터 내에서 다른 호스트에 있는 VM과는 통신할 수 없습니다. 이 문제의 가장 가능성 높은 원인은 무엇입니까?
[정답] B. The VLAN was not created on the upstream switches.
[해설] VLAN ID가 동일한 경우에도, 상위 스위치에 해당 VLAN이 설정되어 있지 않으면 다른 호스트에 있는 VM 간의 통신이 불가능하기 때문에 Nutanix 클러스터 내의 호스트들이 서로 통신하기 위해서는 VLAN이 상위 스위치에서도 일관되게 설정이 필요
Question #4
An administrator logs into the Nutanix Support Portal and notices there is a new version of the LCM Framework available. In an effort to ensure LCM is providing the latest features, the administrator would like to upgrade LCM.
How can the LCM Framework be upgraded?
A. Upload the latest LCM Framework bundle via Upgrade Software in Prism
B. Upload the latest LCM Framework as an image in the Image Configuration in Prism
C. Upgrade AOS
D. Perform an LCM inventory
더보기[문제] 관리자가 Nutanix Support Portal에 로그인하여 LCM Framework의 새로운 버전이 이용 가능하다는 것을 확인했습니다. LCM이 최신 기능을 제공하도록 보장하기 위해, 관리자는 LCM을 업그레이드하고자 합니다.
LCM Framework를 어떻게 업그레이드할 수 있습니까?
[정답] D. Perform an LCM inventory
[해설] LCM은 프레임워크를 자동으로 업데이트하기 때문에 만약 LCM 프레임워크에 대한 업데이트가 가능하다면, LCM은 스스로 업데이트를 수행한 후 작업을 계속 진행
Question #5
On a Nutanix cluster, what does Network Segmentation refer to?
A. Isolating management traffic from storage replication traffic.
B. Physically separating management traffic from guest VM traffic.
C. Isolating intra-cluster traffic from guest VM traffic.
D. A distributed firewall for securing VM to VM traffic.
더보기[문제] Nutanix 클러스터에서 Network Segmentation은 무엇을 의미합니까?
[정답] A. Isolating management traffic from storage replication traffic.
[해설] 스토리지 복제를 위한 별도의 네트워크 세그먼트(LAN)를 생성하여 관리 트래픽과 스토리지 복제(또는 백플레인) 트래픽을 분리
Question #6
Which component can be associated with a storage policy?
A. Catalog
B. VM
C. Category
D. Subnet
더보기[문제] 어떤 구성 요소가 스토리지 정책과 연결될 수 있습니까?
[정답] C. Category
[해설] Nutanix의 스토리지 정책은 특정 카테고리(Category)에 할당할 수 있으며, 이를 통해 해당 카테고리에 속하는 VM이나 애플리케이션에 일관된 스토리지 정책을 적용할 수 있기 때문에 카테고리를 사용하면 유사한 정책이 필요한 리소스를 그룹화하고 관리할 수 있음
Question #7
An administrator needs to update some images that were previously uploaded to their Nutanix cluster. While logged into Prism Element when trying to update the images, the update icon is not enabled.
What could be the cause for this behavior?
A. The files were ISO but were uploaded as disk images hence cannot be used or edited.
B. Images are corrupted and must be re-uploaded.
C. RBAC is configured and the administrator's user doesn't have the right privileges.
D. Images were imported into Prism Central.
더보기[문제] 관리자가 이전에 Nutanix 클러스터에 업로드된 이미지를 업데이트해야 합니다. Prism Element에 로그인한 상태에서 이미지를 업데이트하려고 할 때, 업데이트 아이콘이 활성화되지 않았습니다.
이러한 동작의 원인은 무엇일 수 있습니까?
[정답] D. Images were imported into Prism Central.
[해설] Prism Central로 가져온 이미지는 해당 이미지를 소유한 클러스터에 계속 저장되어 Prism Central은 이미지 메타데이터를 로컬에서만 생성하고 저장하며, 이미지에 대한 작업을 수행할 때 해당 메타데이터를 사용하기 때문에 이미지를 가져온 후에도 가져온 클러스터에서는 이미지가 계속 표시되지만, 시스템에서는 클러스터에서 이미지를 업데이트할 수 없기 때문에 이미지는 Prism Central에서만 업데이트 가능
Question #8
Why has an anomaly been triggered?
A. Because the CPU usage reached 100%.
B. Because the CPU usage crossed the blue band.
C. Because the CPU usage dropped below 20%.
D. Because the blue band range increased over the last 2 days.
더보기[문제] 왜 이상이 발생했습니까?(첨부된 이미지 확인)
[정답] B. Because the CPU usage crossed the blue band.
[해설] 이상 탐지 모듈은 5분마다 사용량을 측정하고, 해당 사용량을 예측된 값과 비교하기 때문에 관측된 값이 허용 범위를 벗어나면, 해당 값을 이상으로 플래그 처리
Question #9
An administrator wants to expand the Failure Domain level of a cluster.
What two options are available? (Choose two.)
A. Data Center
B. Node
C. Block
D. Rack
더보기[문제] 관리자가 클러스터의 장애 도메인(Failure Domain) 수준을 확장하려고 합니다.
어떤 두 가지 옵션을 사용할 수 있습니까? (두 가지 선택)
[정답] C. Block, D. Rack
[해설] Nutanix에서 장애 허용 수준을 변경할 수 있는 유일한 옵션은 Rack Fault Tolerance(랙 장애 허용)와 Block Fault Tolerance(블록 장애 허용)를 설정
Question #10
An administrator is tasked with configuring networking on an AHV cluster and needs to optimize for maximum single VM throughput.
Which bond mode should the administrator select?
A. Active-Active
B. Active-Active with Mac Pinning
C. Active-Backup
D. No Uplink Bond
더보기[문제] 관리자가 AHV 클러스터에서 네트워크 구성을 담당하며, 단일 VM의 최대 처리량(throughput)을 최적화해야 합니다.
관리자가 선택해야 할 Bond 모드는 무엇입니까?
[정답] A. Active-Active
[해설] LACP 및 링크 집계가 필요로 어댑터 간에 VM NIC TCP 및 UDP 세션을 균형 있게 조정하여 단일 10Gb 어댑터를 넘어 호스트 및 VM 대역폭 활용도를 확대하고 네트워크 스위치에 LACP 협상이 필요한 경우에도 사용
PS. 포스팅의 내용은 제 기준으로 작성한 것이기 때문에 참고해서 보시면 감사하겠습니다.
포스팅 과정의 오류 및 오타 그리고 궁금한 점에 대해서는 댓글 남겨주세요.
상업적인 목적으로 무단 복제를 하거나 배포 이용 시 처벌 가능합니다.
728x90반응형'IT Certificate > Nutanix Certification' 카테고리의 다른 글
Nutanix Certified Professional (NCP-MCI) 6.5 문제 풀이 (3) (2) 2024.12.31 Nutanix Certified Professional (NCP-MCI) 6.5 문제 풀이 (2) (8) 2024.12.30 Nutanix Certified Associate (NCA) v6.5 문제 풀이 (7) (2) 2024.12.21 Nutanix Certified Associate (NCA) v6.5 문제 풀이 (6) (6) 2024.12.10 Nutanix Certified Associate (NCA) v6.5 문제 풀이 (5) (4) 2024.12.09